Page #2
|
INSTALLATION MANUAL
|
STEP 1: PAGE 2 OF 2:
|
JOB SITE PREPARATION REMINDERS
- The attachment Channel may need to be counter flashed to the house wall for a water
tight seal.
- If attachment is made to the facia of the house, make sure that the back side of the
fascia and existing eaves do not leak. This can be seen by looking for water stains on the
bottom of the eaves and back of the facia.
- Add a gutter to the existing house if possible to reduce the amount of water on added
room.
WOOD FOUNDATIONS OR DECKS
When securing Bottom tracts to an existing deck or wood foundation, make sure the
counter flashing goes under the entire Bottom Track and overlaps down on to the outside of
the deck. There are no sealants that will bond aluminum to wood, so make sure the flashing
is sealed to the bottom of the Bottom Track with Silicone.
MATERIAL DELIVERY AND SITE PREPARATION
DIAGRAM 1.
DIAGRAM 1.
When the materials have been delivered to the job site, the first step is to lay out
all like materials together.This is done to inventory all the material for the
installation and to be able to select only the material needed for each step. The layout
sheet and the cut list will help in the inventory process.
The material should be placed outside the perimeter of the room being built.
All windows panels and screens should be removed from modules during this step.
|